The Dose Explains Most of the Difference

Each method needs a different amount of product for every pound of dissolved sulfide it controls. Oxygen needs 2 lbs to remove a pound of sulfide, plus enough to keep the flow aerobic for its time in the pipe; calcium nitrate needs about 12 lbs of nitrate (ECO₂ chemical cost comparison, p. 2). Two ECO₂ documents put pure oxygen at about a tenth of the cost of the chemicals used to prevent sewer odor (Superoxygenation: Facts and Myths, p. 1; ECO₂ wastewater brochure, p. 3).

The oxygen dose has two parts: 2 mg/L for every 1 mg/L of sulfide to remove, and the wastewater's oxygen uptake rate, typically 5 to 15 mg/L an hour, times its hours in the pipe (ECO₂ oxygen demand bulletin, pp. 1 to 2). In Grand Rapids, Minnesota, 6 hours at 10 mg/L an hour called for 60 mg/L (Grand Rapids case study, p. 2).

The Dose of Each Method

The dose ECO₂'s comparison gives for each method
MethodDose
Pure oxygen2 lbs of oxygen per lb of sulfide removed, plus the uptake rate times the detention time to prevent new sulfide.
Chlorine (bleach)5 to 15 lbs of sodium hypochlorite per lb of sulfide.
Hydrogen peroxide1 gallon per lb of sulfide.
Calcium nitrateAbout 12 lbs of nitrate per lb of sulfide: 2 to 5 to remove it and 7 to 10 to prevent it.
Iron salts3.3 gallons of ferrous sulfate per lb of sulfide.
Magnesium hydroxide70 to 140 mg/L of the flow, whatever the sulfide level.
Source: ECO₂ chemical cost comparison, p. 2.
A Speece Cone system at a sewer lift station. A pump draws wastewater up from the force main below ground into the top of the Speece Cone. An oxygen supply, a storage tank and a gas vaporizer, feeds pure oxygen to the top of the cone, where it dissolves. The water leaves the cone's rounded bottom with no bubbles and returns to the main.Sewer LiftStationOxygenStorageTankOxygen SupplyOxygen GasVaporizerPumpSpeeceCone®
Fig. 1A Speece Cone system at a sewer lift station. A pump draws a side stream from the force main below ground, the cone dissolves pure oxygen from the oxygen supply into it, and the water returns to the main with no bubbles.

Only Oxygen Takes Dissolved Sulfide to About Zero

Cost is half the comparison; the other half is how low each method pushes the sulfide. ECO₂'s comparison gives pure oxygen about 0 mg/L of dissolved sulfide, hydrogen peroxide about 0.1 mg/L, and chlorine, iron salts and magnesium hydroxide about 0.5 mg/L (ECO₂ chemical cost comparison, p. 2).

That last half milligram matters for concrete, which corrodes at close to half its maximum rate whenever the sewer air holds 2 to 55 ppm of H₂S (ECO₂ gravity sewer note, p. 1). A dose set to stop complaints can still leave the pipe corroding. See crown corrosion and gravity sewer H₂S and corrosion.

What Utilities Paid Before & After the Switch

In Grand Rapids, Minnesota, oxygen replaced calcium nitrate that cost nearly $500,000 a year on a paper mill's 4.3 MGD force main, with 0 ppm of H₂S at the pump station and the clarifiers (Grand Rapids case study, pp. 1 to 2): force main odor control without the chemical. El Paso chose oxygen on lowest life-cycle cost (El Paso case study, p. 1):

Average H₂S on the Frontera Force Main, El PasoCalcium nitrate compared with oxygen, in ppm
  1. With calcium nitrate12 ppm
  2. With oxygen1 ppm

Raymore, Missouri's odor evaluation compared calcium nitrate, ferrous chloride, hydrogen peroxide, potassium permanganate, sodium hypochlorite and three oxygen systems, and found oxygen less expensive than any of the chemicals (Raymore case study, p. 2). St. Joseph, Missouri chose oxygen for its Parkway A force main for the lowest annual operating cost of the alternatives it evaluated.

When a Chemical Is Still the Right Answer

Treating the gas after it forms, with covers, carbon and scrubbers, is the other route; ECO₂'s odor control bulletin calls that treating the symptom (ECO₂ odor control bulletin, p. 1).

Storage, Handling & Side Effects of Each Method

Storage, handling and side effects of each method
MethodStorage and handlingAt the treatment plant
Pure oxygenA liquid in a tank the supplier owns, or made on site. Non-hazardous and non-explosive.No byproducts.
Chlorine (bleach)Hazardous and highly corrosive. Needs secondary containment.May reduce the active biomass the plant relies on.
Hydrogen peroxideHazardous. Needs secondary containment, and may need special training.No byproducts.
Calcium nitrateNon-hazardous.Adds nitrogen to the plant. May increase scum in the wet well.
Iron saltsHazardous and highly corrosive. Needs containment and freeze protection.More solids to handle. May help settling and phosphorus removal.
Magnesium hydroxideA slurry that needs constant mixing, freeze protection and a constant drip.May add alkalinity. The sulfide stays in the water and can return as H₂S.
Source: ECO₂ chemical cost comparison, p. 2. Oxygen supply: liquid oxygen or an onsite generator.

Get the Comparison for Your Own Sewer

Your flow, the pipe's length and diameter, the detention time, the temperature and the sulfide you measure decide it. Send the Force Main Design Data Checklist with a request for a budgetary price, and ECO₂'s engineers will size the oxygen and set its yearly cost against the chemical you use today.

Questions Engineers Ask

How much oxygen does it take to replace a chemical?

2 mg/L of dissolved oxygen for every 1 mg/L of dissolved sulfide to remove, plus the oxygen uptake rate of the wastewater, typically 5 to 15 mg/L an hour, times the detention time. Grand Rapids needed 60 mg/L for 6 hours of detention at 10 mg/L an hour.

When should a utility keep using a chemical?

For short hot spots, where hydrogen peroxide works in 15 to 20 minutes; for very long lines, where calcium nitrate carries through long detention; and lines with several flows joining downstream, which ECO₂'s comparison says oxygen is not intended for.

Are the prices in this guide current?

The chemical cost comparison is undated, and chemical and oxygen prices change by region and year. Send ECO₂ your flow, pipe, detention time and sulfide data with a budgetary price request for a comparison at today's prices.

Sources

Every Paper, Case Study & Note Cited

  1. Odor Control Chemical Cost ComparisonTechnical paper, ECO₂, Undated. Pages 1, 2. PDF: Odor Control Chemical Cost Comparison (opens in a new tab)
  2. Superoxygenation - Facts and MythsTechnical paper, ECO₂, Undated. Page 1. PDF: Superoxygenation - Facts and Myths (opens in a new tab)
  3. ECO₂ Wastewater OxygenationBrochure, ECO₂, May 2023. Page 3. PDF: ECO₂ Wastewater Oxygenation (opens in a new tab)
  4. Tech Bulletin - Oxygen Demand and Solubility CalculationsTechnical paper, ECO₂, Undated. Pages 1, 2. PDF: Tech Bulletin - Oxygen Demand and Solubility Calculations (opens in a new tab)
  5. Grand Rapids, Minn. Plant to Plant H₂S PreventionCase study, October 2023. Pages 1, 2. PDF: Grand Rapids, Minn. Plant to Plant H₂S Prevention (opens in a new tab)
  6. Gravity Sewer Odor and Corrosion ControlApplication note, ECO₂, 2020. Page 1. PDF: Gravity Sewer Odor and Corrosion Control (opens in a new tab)
  7. El Paso, TX Frontera Lift Station Replaces Chemical Feed System with OxygenCase study, ECO₂, Undated. Pages 1, 2. PDF: El Paso, TX Frontera Lift Station Replaces Chemical Feed System with Oxygen (opens in a new tab)
  8. Raymore, MO Stops Extreme H2S Problems with OxygenCase study, ECO₂, Undated. Page 2. PDF: Raymore, MO Stops Extreme H2S Problems with Oxygen (opens in a new tab)
  9. Tech Bulletin - Comparing Odor Control Strategies in WastewaterTechnical paper, ECO₂, Undated. Page 1. PDF: Tech Bulletin - Comparing Odor Control Strategies in Wastewater (opens in a new tab)

Cite this guide: Eco Oxygen Technologies. Odor Control Chemicals vs Oxygen: What Each One Costs. ECO₂ Guides, November 2026. https://eco2tech.com/guides/odor-control-chemicals-vs-oxygen-cost/

The Next Step

Get the Numbers for Your Own Sewer or Plant

Tell us about your site and ECO₂'s engineers will size a system and send a budgetary price.

A stainless steel Speece Cone with its side stream pump and controls at a fenced pump station among pine trees