Kennebunk Sewer District Dissolved Oxygen Discharge Compliance
ECO₂'s case study of Kennebunk Sewer District in Maine, which adds dissolved oxygen to its treated effluent to meet its permit for discharge into an impaired waterway.
Details
Summary
Kennebunk Sewer District's 2006 permit renewal said its plant discharge must not lower water quality in the Mousam River Estuary, which is impaired for dissolved oxygen. With Woodard & Curran, the district upgraded the plant and chose ECO₂ Superoxygenation to raise effluent oxygen to saturation or higher at over 90% transfer efficiency. Since installation in 2006, effluent D.O. has averaged 9.2 mg/L in the hot summer months.
Key Figures
9.2mg/L
Average effluent D.O. in the hot summer months after installation Source: PDF page 2 (opens in a new tab)
90%oxygen transfer efficiency
Speece Cone® oxygen transfer efficiency (over) Source: PDF page 1 (opens in a new tab)
10years
Successful operation of the system (over) Source: PDF page 2 (opens in a new tab)
Questions
What did Kennebunk's discharge permit require?
The 2006 NPDES permit renewal said the plant's discharge must not lower the quality of the Mousam River Estuary, which is impaired for dissolved oxygen depletion. (PDF page 1) (opens in a new tab)
What solution did the district choose?
Plant upgrades to cut solids and BOD in the effluent, plus oxygenating the effluent to saturated D.O. or higher. After comparing aeration and oxygenation technologies on performance and life costs, the district selected ECO₂ Superoxygenation, which transfers oxygen at over 90% efficiency. (PDF page 1) (opens in a new tab)
How does the system perform in summer?
Hot summer months used to be the hardest time to meet the effluent D.O. limit. Since the 2006 installation, effluent D.O. has averaged 9.2 mg/L in those months, and the system has run successfully for over 10 years. (PDF page 2) (opens in a new tab)
In Full
More Key Figures
One more, each with what it measures and its PDF page.
From the PDF
| Figure | What It Measures |
|---|---|
| 2006 | Year of the permit renewal and of the ECO₂ installation (PDF page 2 (opens in a new tab)) |
Full Text as Published
The text as its authors wrote it.
Plant Effluent Dissolved Oxygen through SuperOxygenation
The Kennebunk Sewer District's 2006 NPDES permit renewal dictated that the discharge from the town's POTW must not lower the quality of the water body it discharges into – the Mousam River Estuary. The estuary is considered impaired with respect to depletion of dissolved oxygen (D.O.). To meet permit requirements in conjunction with a plant upgrade, Kennebunk Sewer District and Woodard & Curran worked with the State to consider all parameters that potentially impact estuary D.O. levels in the estuary. Parameters such as effluent D.O., TSS, BOD, and nutrients were evaluated regarding treatment technologies and expected impact on the D.O. levels in the estuary.
The solution included plant upgrades to minimize solids and BOD in the effluent, and to oxygenate the plant effluent to saturated D.O. levels or greater. To meet this requirement, Kennebunk investigated several aeration and oxygenation technologies, focusing on the ability to meet stated goals and overall capital and operational costs for project life costs. The District selected the ECO₂ SuperOxygenation System. This technology uses a conical transfer reactor, also known as the Speece Cone, to dissolve pure oxygen into water at an oxygen transfer efficiency of over 90%.
Mousam River Marsh (Photo Credit: Bud in Wells, Maine).
Results
Historically, the hot summer months were most difficult to meet the effluent D.O. limit. The graph in the PDF shows an average effluent D.O. level of 9.2 mg/L during those hot summer months after the installation of the ECO₂ system in 2006. The system has been successfully operating for over 10 years.
Installation of ECO₂ system at the Kennebunk WWTP Effluent.
How to Cite
One line to paste into a report.
Kennebunk Sewer District Dissolved Oxygen Discharge Compliance. ECO₂, 2015. Project engineer: Woodard & Curran. Eco Oxygen Technologies Technical Library. https://eco2tech.com/technical-library/kennebunk-sewer-district-dissolved-oxygen-discharge-compliance/
https://eco2tech.com/technical-library/kennebunk-sewer-district-dissolved-oxygen-discharge-compliance/
The Next Step
Ask an ECO₂ Engineer
Questions about this case study, or about your own water? An application engineer answers, with the figures.