Fishers, IN Odor and Corrosion Control for Collections and Plant Headworks
ECO₂'s case study from Fishers, Indiana, where oxygen at three lift stations protects the collection system and the plant headworks from odor and corrosion.
Details
Summary
The Town of Fishers, IN installed ECO₂ Superoxygenation systems at its three lift stations to stop odor complaints at the Cheeney Creek WWTP headworks and a nearby lift station. Oxygenating all plant influent prevents hydrogen sulfide from forming, and the plant typically sees about 5 mg/L of dissolved oxygen at its inlet. All three systems have run for over 15 years, and the WWTP Director calls them hands-free.
Key Figures
5mg/L
Typical dissolved oxygen entering the WWTP (about) Source: PDF page 2 (opens in a new tab)
15years
Successful operation of all three systems (over) Source: PDF page 2 (opens in a new tab)
100%
Share of flow to Cheeney Creek WWTP treated by Superoxygenation Source: PDF page 2 (opens in a new tab)
Questions
Why did Fishers choose Superoxygenation?
Odors from the Cheeney Creek WWTP headworks and a nearby lift station drew frequent complaints in an upscale residential area. The town chose the ECO₂ system over gas scrubbers for its environmentally friendly process and expected operating costs well below chemical treatment. (PDF page 1) (opens in a new tab)
Where are the systems installed?
At each of the three lift stations (Allisonville Rd, Smock Creek and Hague Rd) that feed the plant's two long force mains, so all plant influent is pretreated. (PDF page 1) (opens in a new tab)
How does the system work?
A sidestream of raw wastewater is pumped through the Speece Cone®, pure oxygen is metered into the cone, and the oxygenated wastewater is blended back into the force main. Fishers uses liquid oxygen delivered by a local supplier and stored on site. (PDF page 2) (opens in a new tab)
How well has it performed?
Dissolved oxygen entering the WWTP is typically about 5 mg/L, and all three systems have operated successfully for over 15 years. (PDF page 2) (opens in a new tab)
What does it cost to operate?
The WWTP Director describes the systems as hands-free: the only O&M costs are the liquid oxygen supply and regular maintenance on the sidestream pumps. (PDF page 2) (opens in a new tab)
In Full
More Key Figures
One more, each with what it measures and its PDF page.
From the PDF
| Figure | What It Measures |
|---|---|
| three lift stations | Systems installed, one at each lift station feeding the plant (PDF page 1 (opens in a new tab)) |
Full Text as Published
The text as its authors wrote it.
Preventing Odors & Corrosion through SuperOxygenation
The Cheeney Creek Wastewater Treatment Plant (WWTP) is located in an upscale residential area of Fishers, IN, a fast-growing suburb of Indianapolis. Odor from the plant's headworks and a nearby lift station were sources of frequent complaints.
The Town wanted to address odor complaints and be a good neighbor. The ECO₂ SuperOxygenation system was chosen to supersede gas scrubbers because of its environmentally friendly process. In addition, operating costs were expected to be significantly less than the alternative chemical treatments.
The plant receives its influent from two long force mains, fed from three lift stations. The ECO₂ SuperOxygenation system was installed at each lift station to pretreat all plant influent to prevent the formation and release of hydrogen sulfide (H2S): Allisonville Rd Lift Station, Smock Creek Lift Station and Hague Rd Lift Station.
Project Goals
- Zero dissolved sulfides at WWTP influent
- Positive D.O. at WWTP influent
- Reduce odors at lift stations & headworks
- Reduce corrosion in force mains
How It Works
The ECO₂ technology eliminates hydrogen sulfide odor and corrosion by dissolving pure oxygen in wastewater at high concentrations, which oxidizes any existing sulfides and prevents the formation of dissolved sulfides and hydrogen sulfide gas.
The system operates by pumping a sidestream of raw wastewater through a conical shaped oxygen-transfer device (Speece Cone). Pure oxygen gas is metered into the cone, and the oxygenated wastewater is blended back into the force main.
Pure oxygen can be sourced locally or generated on-site. Fishers, IN uses liquid oxygen (LOX), which is delivered by a local supplier and stored on-site.
Results
Successful performance of the ECO₂ system is evident by typical dissolved oxygen (D.O.) levels of about 5 mg/L entering the WWTP. All three of the systems in Fishers, IN have been in successful operation, for over 15 years. Richard Farnham, WWTP Director describes these systems as "hands-free" as the only O&M costs are the supply of LOX and regular pump maintenance on the sidestream pumps.
Odor Control System Schematic: 100% of flow to Cheeney Creek WWTP treated by ECO₂ SuperOxygenation Technology.
How to Cite
One line to paste into a report.
Fishers, IN Odor and Corrosion Control for Collections and Plant Headworks. ECO₂. Project engineer: Commonwealth Engineers. Eco Oxygen Technologies Technical Library. https://eco2tech.com/technical-library/fishers-in-odor-and-corrosion-control-for-collections-and-plant-headwoks/
https://eco2tech.com/technical-library/fishers-in-odor-and-corrosion-control-for-collections-and-plant-headwoks/
The Next Step
Ask an ECO₂ Engineer
Questions about this case study, or about your own water? An application engineer answers, with the figures.