St. Petersburg, FL Lift Stations Odor and Corrosion Control

ECO₂'s case study of St. Petersburg, Florida, where Speece Cones® at two lift stations keep H₂S from forming in long force mains and cut odor and corrosion at the plant.

Details

Publisher
ECO₂
Published
April 2025

Summary

St. Petersburg's Southwest Water Reclamation Facility treats about 20 MGD fed by two large force mains from Lift Stations 28 and 85, which would otherwise generate hydrogen sulfide, odor and corrosion. As part of the city's sustainability initiative, ECO₂ Speece Cone Superoxygenation systems with liquid oxygen supply replaced traditional odor control chemicals. Lift Station 28 (installed 2024) treats a 20 inch, 3 mile force main with 1,100 lbs/day of pure oxygen; Lift Station 85 (installed 2023) treats a 30 inch, 7 mile force main with 3,300 lbs/day. Both cones are 5 ft in diameter.

Key Figures

Questions

Why did St. Petersburg add oxygen to these force mains?

The two force mains feeding the Southwest Water Reclamation Facility would otherwise produce significant H₂S, causing odor and corrosion, and the city wanted to cut chemical use under its sustainability initiative. (PDF page 1) (opens in a new tab)

What was installed at Lift Station 28?

A 5 ft ECO₂ Speece Cone with liquid oxygen supply, dissolving 1,100 lbs/day of pure oxygen into a 20 inch, 3 mile force main; installed in 2024. (PDF page 1) (opens in a new tab)

What was installed at Lift Station 85?

A 5 ft ECO₂ Speece Cone with liquid oxygen supply, dissolving 3,300 lbs/day of pure oxygen into a 30 inch, 7 mile force main; installed in 2023. (PDF page 2) (opens in a new tab)

What results does the case study list?

Reduced costs, odors eliminated and infrastructure protected. (PDF page 2) (opens in a new tab)

The Projects

Lift Station 28

Location
St. Petersburg, Florida
Application
Wastewater Odor Control
Capacity
1,100 lbs/day
See the Project

Lift Station 85

Location
St. Petersburg, Florida
Application
Wastewater Odor Control
Capacity
3,300 lbs/day
See the Project

In Full

More Key Figures

Five more, each with what it measures and its PDF page.

From the PDF

FigureWhat It Measures
3,300 lbs/day
Pure oxygen dissolved at Lift Station 85 (PDF page 2 (opens in a new tab))
7-mile force main
Length treated from Lift Station 85 (30 inch diameter) (PDF page 2 (opens in a new tab))
5 ft
Diameter of each Speece Cone (PDF page 1 (opens in a new tab))
2024
Year the Lift Station 28 system was installed (PDF page 1 (opens in a new tab))
2023
Year the Lift Station 85 system was installed (PDF page 2 (opens in a new tab))

Full Text as Published

The text as its authors wrote it.
The case study's own words, as published. Its figures are the authors'; the PDF (2 pages) is the original, with the figures, photos and tables drawn as images.

Case Study: Odor Control, Saint Petersburg, FL

Lift Station 28

The Southwest Water Reclamation Facility (SWWRF) processes about 20 million gallons per day (MGD) of wastewater for the City of St. Petersburg. The wastewater treatment plant is fed by two large force mains leaving Lift Station 28 and Lift Station 85. These two force mains if left untreated would cause significant Hydrogen Sulfide (H₂S) leading to odor and corrosion issues. As part of the City's sustainability initiative, an alternative to traditional odor control chemicals was needed to reduce chemical use and lower H₂S levels.

ECO₂ Speece Cone Superoxygenation system installed at Lift Station 28 Including Liquid Oxygen Supply (LOX) system.

ECO₂ Speece Cone Superoxygenation System

An ECO₂ Speece Cone Superoxygenation System was installed at Lift Station 28 to treat the 20" diameter, 3-mile long force main to prevent H₂S formation to reduce odors and corrosion at the SWWRF influent in the treatment plant. The ECO₂ Speece Cone is 5 feet in diameter and dissolves 1,100 lbs/day of pure oxygen.

ApplicationOdor & Corrosion Prevention
ConsultantSt. Petersburg Water Resources
O₂ Capacity1,100 lbs/day
O₂ SupplyLOX Storage Tank
Installed2024
Lift Station 85

The Southwest Water Reclamation Facility (SWWRF) processes about 20 million gallons per day (MGD) of wastewater for the City of St. Petersburg. The wastewater treatment plant is fed by two large force mains leaving Lift Station 28 and Lift Station 85. These two force mains if left untreated would cause significant Hydrogen Sulfide (H₂S) leading to odor and corrosion issues. As part of the City's sustainability initiative, an alternative to traditional odor control chemicals was needed to reduce chemical use and lower H₂S levels.

ECO₂ Speece Cone Superoxygenation system installed at Lift Station 85 Including Liquid Oxygen Supply (LOX) system.

ECO₂ Speece Cone Superoxygenation System

An ECO₂ Speece Cone Superoxygenation System was installed at Lift Station 85 to treat the 30" diameter, 7-mile long force main to prevent H₂S formation to reduce odors and corrosion at the SWWRF influent in the treatment plant. The ECO₂ Speece Cone is 5 feet in diameter and dissolves 3,300 lbs/day of pure oxygen.

ApplicationOdor & Corrosion Prevention
ConsultantSt. Petersburg Water Resources
O₂ Capacity3,300 lbs/day
O₂ SupplyLOX Storage Tank
Installed2023
  • Summary: Sewer Collections, St Petersburg, FL
  • Problem: Odor Complaints; H₂S Corrosion
  • Solution: Superoxygenation
  • Results: Reduced Costs; Odors Eliminated; Infrastructure Protected

How to Cite

One line to paste into a report.

St. Petersburg, FL Lift Stations Odor and Corrosion Control. ECO₂, April 2025. Eco Oxygen Technologies Technical Library. https://eco2tech.com/technical-library/st-petersburg-fl-lift-stations-odor-and-corrosion-control/