St. Petersburg, FL Lift Stations Odor and Corrosion Control
ECO₂'s case study of St. Petersburg, Florida, where Speece Cones® at two lift stations keep H₂S from forming in long force mains and cut odor and corrosion at the plant.
Details
Summary
St. Petersburg's Southwest Water Reclamation Facility treats about 20 MGD fed by two large force mains from Lift Stations 28 and 85, which would otherwise generate hydrogen sulfide, odor and corrosion. As part of the city's sustainability initiative, ECO₂ Speece Cone Superoxygenation systems with liquid oxygen supply replaced traditional odor control chemicals. Lift Station 28 (installed 2024) treats a 20 inch, 3 mile force main with 1,100 lbs/day of pure oxygen; Lift Station 85 (installed 2023) treats a 30 inch, 7 mile force main with 3,300 lbs/day. Both cones are 5 ft in diameter.
Key Figures
20MGD
Wastewater treated at the Southwest Water Reclamation Facility (about) Source: PDF page 1 (opens in a new tab)
1,100lbs/day
Pure oxygen dissolved at Lift Station 28 Source: PDF page 1 (opens in a new tab)
3-mileforce main
Length treated from Lift Station 28 (20 inch diameter) Source: PDF page 1 (opens in a new tab)
Questions
Why did St. Petersburg add oxygen to these force mains?
The two force mains feeding the Southwest Water Reclamation Facility would otherwise produce significant H₂S, causing odor and corrosion, and the city wanted to cut chemical use under its sustainability initiative. (PDF page 1) (opens in a new tab)
What was installed at Lift Station 28?
A 5 ft ECO₂ Speece Cone with liquid oxygen supply, dissolving 1,100 lbs/day of pure oxygen into a 20 inch, 3 mile force main; installed in 2024. (PDF page 1) (opens in a new tab)
What was installed at Lift Station 85?
A 5 ft ECO₂ Speece Cone with liquid oxygen supply, dissolving 3,300 lbs/day of pure oxygen into a 30 inch, 7 mile force main; installed in 2023. (PDF page 2) (opens in a new tab)
What results does the case study list?
Reduced costs, odors eliminated and infrastructure protected. (PDF page 2) (opens in a new tab)
The Projects

Lift Station 28

Lift Station 85
In Full
More Key Figures
Five more, each with what it measures and its PDF page.
From the PDF
| Figure | What It Measures |
|---|---|
| 3,300 lbs/day | Pure oxygen dissolved at Lift Station 85 (PDF page 2 (opens in a new tab)) |
| 7-mile force main | Length treated from Lift Station 85 (30 inch diameter) (PDF page 2 (opens in a new tab)) |
| 5 ft | Diameter of each Speece Cone (PDF page 1 (opens in a new tab)) |
| 2024 | Year the Lift Station 28 system was installed (PDF page 1 (opens in a new tab)) |
| 2023 | Year the Lift Station 85 system was installed (PDF page 2 (opens in a new tab)) |
Full Text as Published
The text as its authors wrote it.
Case Study: Odor Control, Saint Petersburg, FL
Lift Station 28
The Southwest Water Reclamation Facility (SWWRF) processes about 20 million gallons per day (MGD) of wastewater for the City of St. Petersburg. The wastewater treatment plant is fed by two large force mains leaving Lift Station 28 and Lift Station 85. These two force mains if left untreated would cause significant Hydrogen Sulfide (H₂S) leading to odor and corrosion issues. As part of the City's sustainability initiative, an alternative to traditional odor control chemicals was needed to reduce chemical use and lower H₂S levels.
ECO₂ Speece Cone Superoxygenation system installed at Lift Station 28 Including Liquid Oxygen Supply (LOX) system.
ECO₂ Speece Cone Superoxygenation System
An ECO₂ Speece Cone Superoxygenation System was installed at Lift Station 28 to treat the 20" diameter, 3-mile long force main to prevent H₂S formation to reduce odors and corrosion at the SWWRF influent in the treatment plant. The ECO₂ Speece Cone is 5 feet in diameter and dissolves 1,100 lbs/day of pure oxygen.
| Application | Odor & Corrosion Prevention |
| Consultant | St. Petersburg Water Resources |
| O₂ Capacity | 1,100 lbs/day |
| O₂ Supply | LOX Storage Tank |
| Installed | 2024 |
Lift Station 85
The Southwest Water Reclamation Facility (SWWRF) processes about 20 million gallons per day (MGD) of wastewater for the City of St. Petersburg. The wastewater treatment plant is fed by two large force mains leaving Lift Station 28 and Lift Station 85. These two force mains if left untreated would cause significant Hydrogen Sulfide (H₂S) leading to odor and corrosion issues. As part of the City's sustainability initiative, an alternative to traditional odor control chemicals was needed to reduce chemical use and lower H₂S levels.
ECO₂ Speece Cone Superoxygenation system installed at Lift Station 85 Including Liquid Oxygen Supply (LOX) system.
ECO₂ Speece Cone Superoxygenation System
An ECO₂ Speece Cone Superoxygenation System was installed at Lift Station 85 to treat the 30" diameter, 7-mile long force main to prevent H₂S formation to reduce odors and corrosion at the SWWRF influent in the treatment plant. The ECO₂ Speece Cone is 5 feet in diameter and dissolves 3,300 lbs/day of pure oxygen.
| Application | Odor & Corrosion Prevention |
| Consultant | St. Petersburg Water Resources |
| O₂ Capacity | 3,300 lbs/day |
| O₂ Supply | LOX Storage Tank |
| Installed | 2023 |
- Summary: Sewer Collections, St Petersburg, FL
- Problem: Odor Complaints; H₂S Corrosion
- Solution: Superoxygenation
- Results: Reduced Costs; Odors Eliminated; Infrastructure Protected
How to Cite
One line to paste into a report.
St. Petersburg, FL Lift Stations Odor and Corrosion Control. ECO₂, April 2025. Eco Oxygen Technologies Technical Library. https://eco2tech.com/technical-library/st-petersburg-fl-lift-stations-odor-and-corrosion-control/
https://eco2tech.com/technical-library/st-petersburg-fl-lift-stations-odor-and-corrosion-control/