Breathing Easy Again in El Paso Texas - MSW Article

An MSW article on how El Paso Water keeps dissolved oxygen in the wastewater on its way to the Hickerson plant, and how that largely stopped the plant's odor complaints.

Details

Publisher
Municipal Water & Sewer Magazine
Published
October 2020
Author
Kyle Rogers
Engineer
Jacobs

Summary

A Municipal Sewer & Water feature from October 2020 on how El Paso Water ended years of odor complaints at its John T. Hickerson Water Reclamation Facility.

Key Figures

Questions

How much did El Paso's Superoxygenation system cost?

Nearly $1.1 million in total, split almost evenly between ECO Oxygen Technologies for the equipment and a contractor for the installation. (PDF page 5) (opens in a new tab)

Why did El Paso Water choose Superoxygenation over other options?

According to David Ornelas, it had the lowest life-cycle cost of the liquid phase treatment options, and it avoided building more air treatment at the plant. (PDF page 4) (opens in a new tab)

Does Superoxygenation reduce force main corrosion in El Paso?

Yes. Besides controlling odor, it has reduced corrosion in the 3 1/2 miles of force main between the lift station and the plant, which the utility values because replacing force mains is costly. (PDF page 4) (opens in a new tab)

The Project

Frontera Pump Station

Location
El Paso, Texas
Application
Wastewater Odor Control
Capacity
5,000 lbs/day
See the Project

In Full

More of the Summary

Two more paragraphs of our summary.

The Hickerson plant has no primary clarifiers and sits in a low area beside an interstate, homes and businesses. An odor assessment in 2012 by JACOBS found high sulfide levels at Frontera, where a simple diffuser system could not keep up. The utility chose it because it had the lowest life-cycle cost of the liquid phase options.

The project cost nearly $1.1 million, split almost evenly between equipment and installation, and reused the oxygen supply already on site. Besides stopping odor complaints, it reduced corrosion along the force mains and the chemicals used in the plant's scrubbers, and avoided building more air treatment at the plant. El Paso Water is now looking at the Fred Hervey Water Reclamation Plant for the same approach.

More Key Figures

Two more, each with what it measures and its PDF page.

From the PDF

FigureWhat It Measures
3 1/2 miles
Force main length from the Frontera Lift Station to the Hickerson plant (PDF page 3 (opens in a new tab))
24 feet
Height of the Speece Cone® above the force mains (PDF page 5 (opens in a new tab))

How to Cite

One line to paste into a report.

Kyle Rogers. Breathing Easy Again in El Paso Texas - MSW Article. Municipal Water & Sewer Magazine, October 2020. Project engineer: Jacobs. Eco Oxygen Technologies Technical Library. https://eco2tech.com/technical-library/breathing-easy-again-in-el-paso-texas-msw-article/

https://eco2tech.com/technical-library/breathing-easy-again-in-el-paso-texas-msw-article/

The Next Step

Ask an ECO₂ Engineer

Questions about this published article, or about your own water? An application engineer answers, with the figures.